Front Panel Operation
MN/CLO-10.IOM
6.4.5 CONFIG: Remod (Remodulation Parameters)
Remod: Frequency On/Off
Attenuation (◄ ► ENT)
Select Frequency, On/Off, or Attenuation using the ◄ ► arrow keys, then press
ENTER
.
CONFIG: Remod ÆFrequency
If Frequency is selected:
Remod: Frequency
0070.0000 MHz (◄ ► ▲ ▼ ENT)
Edit the IF Remod Frequency by selecting the digit to be edited, using the W X arrow keys. The
value of the digit is then changed using the ST arrow keys. The range of frequencies is 50-90
MHz and 100-180 MHz with 100 Hz resolution.
Once the IF Remod Frequency is edited, the user should press
ENTER.
CONFIG: Remod Æ On/Off
If On/Off is selected:
Output State: Off On
(◄ ► ENT)
Edit the Output State for this unit. Select either On or Off using the W X arrow keys, then press
ENTER
.
CONFIG: Remod Æ Attenuation
If Attenuation is selected:
Attenuation:
00.0 dB (◄ ► ▲ ▼ ENT)
Edit the Attenuation for this unit. Editing the value is accomplished by selecting the digit to be
edited, using the W X arrow keys. The value of the digit is then changed using the ST arrow
keys. The range varies 0-31.5 dB in 0.5 dB steps.
Once the Attenuation is edited, the user should press
ENTER
.