D.3.4.7.2 Argument Lists
In order to enforce atomic reads and writes, and to also allow for checking related parameter for validity, multi-argument lists have the
following format:
• Arguments are positioned in fixed length format (see specification for each argument).
• ‘|’ Is used to separate different argument values from each other.
D.3.4.8 End of Packet
Controller-to-Target: This is the 'Carriage Return' character (ASCII code 13).
Target-to-Controller: This is the two-character sequence 'Carriage Return' (ASCII code 13), and 'Line Feed' (ASCII code 10).