Comtech EF Data CDD-562L User Manual
Page 144

CDD-562L/564 Demodulator with IP Module
Revision 2
CDD-56X CLI and Telnet Operation
MN/CDD564L.IOM
8–40
Selection
Entry
Description
PARAM Image
C
Identifies the PARAM file that will be loaded on bootup. The options
are:
1. Factory – Uses the internal, hard-coded factory default
parameters.
2. PARAM – Last saved Parameter file.
Statistics
T
Opens Statistics Menu page.
Event Log
E
Opens Event Log page.
Database Operations
D
Opens administrative Database Operations page.
Reset
R
Allows user to reboot the Unit. This has the same logical effect of
power-cycling the unit.
Diagnostics
G
Opens Diagnostics page.
M&C Interface
F
Provides user access to the demodulator’s available remote product
management commands and queries.
Once the M&C Interface is selected, at the ‘#’ prompt a Controller-to-
Target remote command or query takes the following form:
• Start of Packet ‘<’
• Address Delimiter ‘/’
• Target Address (1-4 characters, 0001 – 0004)
• 3-character Instruction Code (e.g., RFQ)
• Instruction Code Qualifier – Command ‘=’ or Query ‘?’
Example: M&C CLI INTERFACE
(X=Exit) #<1/RFQ?
>0001/RFQ=1200.0000
When finished, type ‘X’ to exit the M&C Interface and return to the
Operations and Maintenance page.
Appendix D. CDM/CDD NMCS REMOTE PRODUCT
MANAGEMENT PROTOCOL