Comtech EF Data CDD-562L User Manual
Page 159

CDD-562L/564 Demodulator with IP Module
Revision 2
CDD-56X CLI and Telnet Operation
MN/CDD564L.IOM
8–55
Selection
Entry Description
Dump Packets sent to
EndStation
G
Select [Yes] or [No].
Selecting [Yes] forces the IP Module to dump a hexadecimal
representation of each packet that is received/destined for the
demodulator only.
Dump Packets received from
EndStation
H
Select [Yes] or [No].
Selecting [Yes] forces the IP Module to dump a hexadecimal
representation of each packet that is sourced from this unit and
destined for some other device. This Allows user to see what type of
packets this unit is generating internally.
Ping
P
Enter the IP address in aaa.bbb.ccc.ddd format to ping, on the same
subnet as CDD-56x unit.
Traceroute
A
Enter the IP address in aaa.bbb.ccc.ddd format
Command Line Debug Prompt
D
Enter the password to access the debug command line.
Note: This option is reserved for Customer Service and
engineering use only.