Compuprint 10200 Programmer Manual User Manual
Page 103
Commands
99
2 of 5
DC4 DC4 ESC!
n 16 p EM
Bidirectional
BID-25 bar code data fields do not have a defined format length and contain
numeric data only: question marks will be printed in place of HRC string
otherwise, if possible. If o check digit option field takes 1 value an internally
generated check digit will be added to the encoded string, that however will not
show on the required HRC string.
2 of 5
DC4 DC4 ESC!
n 17 p EM
Interleaved
The 2/5-INTERLEAVED bar code does not have a defined format length.
However, the total sum of the characters must be even. n indicates the bar code
height and must be in the range 1 to 12. p must be NUL (hex. 00) if no Human
Readable Characters are to be printed, and 1 (hex. 01) if they are to be printed.
2 of 5
DC4 DC4 ESC !
n 18 p EM
Industrial
The 2/5 INDUSTRIAL bar code. Data format length is variable and the
supported character set only provides ASCII numeric figures 0 to 9. N indicates
the bar code height in units of 1/6 inch and must be in the range 1 to 12. P must
be NUL (hex. 00) if no Human Readable Characters are to be printed, and 1
(hex. 01) if they are to be printed.