3 led controls, Table 3-2, Led control indicator – Artesyn MITX-CORE-820 Installation and Use (July 2014) User Manual
Page 50: Controls, leds and connectors

Controls, LEDs and Connectors
MITX-CORE-820 Installation and Use (6806800M10H)
50
With the exception of the Mini-DIN DC-IN connector , LVDS, LVDS inverter connector and eDP
connector, all connectors used for the MITX-CORE-820 are standard connectors available in
the market. SATA power cables are provided with the MITX-CORE-820. Please contact your
local Artesyn representatives for information on the Mini-DIN DC-IN connector, LVDS, LVDS
inverter connector and eDP connectors.
3.3
LED Controls
The MITX-CORE-820 has one green LED and one red LED to indicate the charging and
discharging status. Only a charging board is needed for battery management as the LED is fully
controlled by the EC.
P23
CPU Fan Header
See
J15
eDP Connector
See
Embedded Display Port (eDP), on page 58
J11
Audio Jack
See
J13
DC-IN Jack
See
J12
ATX Power Supply Connector
See
Table 3-1 MITX-CORE-820 Connectors (continued)
Reference
Designator
Function
Pinout Definition
Table 3-2 LED Control Indicator
Battery Status
Green LED Status
Red LED Status
Charging
Inactive
Active
Fully Charged
Active
Inactive
Discharging
Inactive
Inactive
Battery Low
Inactive
Blinking