6.2.8

EC Command Program Sequence

6.2.9

EC Space Definition

Table 6-6 EC Command Program Sequence

Command Byte

Command Name

Programming Sequence

80h

Read EC

Write EC_CMD with 80h
Write address byte to EC_DAT
Wait SCI for OBF=1
Read EC_DAT with data in

81h

Write EC

Write EC_CMD with 81h
Wait SCI for IBF=0
Write address byte to EC_DAT
Wait SCI for IBF=0
Write data byte to EC_DAT
Wait SCI for IBF=0

82h

Burst Enable

Write EC_CMD with 82h
Wait SCI for OBF=1
Read EC_DAT with 90h

83h

Burst Disable

Write EC_CMD with 83h
Wait SCI for IBF=0

84h

Query EC

Write EC_CMD with 84h
Wait SCI for OBF=1
Read EC_DAT with SCI ID number

Table 6-7 EC Space Definition

Table Offset

Length (Bytes)

Description

0x00

1

Thermal Version

0x01

1

Maximum Fan Level Support