Firmware Upgrade Facility

ATCA-MF106 Installation and Use (6806800M62B)

74

--upgrade --file=

--upgrade --mark --file=

--upgrade --file= --target=xxxxxx

--verify --file=

--verify --upgrade --file=

--activate --bank= --device=

--verify --upgrade --mark --file=

--version

Multi character options may be abbreviated so long as they are unique. For example, --full
is equivalent to --full-upgrade. Typing --ver, however, will not work since it matches
both --verify and --version.

Single-character options may be combined without repeating the hyphen, as in these
examples:

fcu –vf /opt/bladeservices/rom/

fcu –q –d

fcu –q -t 0x90

fcu –mb a –d

Options are not case-sensitive. For example, --help is equivalent to --HeLp. However,
option arguments, such as filename and device ID, are case-sensitive.

When upgrading firmware, it is strongly recommended that you upgrade only one device at a
time. While FCU performs many checks during upgrade to ensure success, if something goes
wrong and both firmware banks become corrupted, the blade will be inoperable.