2 power requirements, Table 4-2, Dc board power requirements – Artesyn ATCA-MF106 Installation and Use (September 2014) User Manual
Page 57: Board exchange

Board Exchange
ATCA-MF106 Installation and Use (6806800M62B)
57
4.2.1.2
Power Requirements
Make sure that the board is used in an AdvancedTCA shelf connected to -48 VDC up to -60 VDC
(rated voltage), according to Telecommunication Network Voltage (TNV-2).
A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra-
low-voltage (SELV) under normal operating conditions, and which is not subject to
overvoltages from telecommunication networks.
On board voltages are 3.3 VDC, 2.5 VDC, 1.8 VDC and 1.0 VDC:
3.3 V voltage is generated from the -48 V AdvancedTCA power by a DC/DC converter with
galvanic isolation suitable for TNV-2 circuits.
2.5 V, 1.8 V and 1.0 V voltages are derived from the 3.3 V power.
Shock
Half-sine, 11 mSec, 30 m/Sec
2
Blade level packaging
Half-sine, 6 mSec at 180 m/Sec
2
Free fall
-
200 mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(Blade level packaging)
100 mm (unpackaged) per GR-63-CORE
Table 4-1 Environmental Requirements (continued)
Feature
Operating
Non-Operating (packed state)
Table 4-2 DC Board Power Requirements
Feature
Value
Rated Voltage
-48 VDC to -60 VDC
US and Canada: -48 VDC
Operating Voltage
-39 VDC to -72 VDC
US and Canada: -39 VDC to -60 VDC
Input current
0.2 A
ATCA-MF106 power dissipation
10 W (max.) including external load of 4 W maximum