1 environmental requirements, Table 4-1, Environmental requirements – Artesyn ATCA-MF106 Installation and Use (September 2014) User Manual
Page 56: Board exchange

Board Exchange
ATCA-MF106 Installation and Use (6806800M62B)
56
4.2.1.1
Environmental Requirements
You must make sure that the board, when operated in your particular system configuration,
meets the environmental requirements specified below.
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Board Damage
High humidity and condensation on the board surface causes short circuits.
Do not operate the board outside the specified environmental limits. Make sure the board
is completely dry and there is no moisture on any surface before applying power.
Table 4-1 Environmental Requirements
Feature
Operating
Non-Operating (packed state)
Temperature
+5 ºC (+41 °F) to +40 ºC (+104 °F)
(normal operation) according to NEBS
Standard GR-63-CORE
-5 °C (+23 °F) to + 55 °C (+131 °F)
(exceptional operation) according to
NEBS Standard GR-63-CORE
-40 ºC (-40 °F) to +85 ºC (+185 °F)
Temp. change
+/- 0.25 ºC/min according to NEBS
Standard GR-63-CORE
+/- 0.25 ºC/min
Relative humidity 5% to 90% non-condensing according
to Artesyn Embedded Technologies-
internal environmental requirements
5% to 95% non-condensing according to
Artesyn Embedded Technologies-
internal environmental requirements
Vibration (tested
in target
platform)
0.1 g from 5 to 100 Hz and back to 5 Hz
at a rate of 0.1 octave/minute.
5-20 Hz at 0.01 g
2
/Hz
20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 m
2
/Sec
3
Random 20-200 Hz at -3 dB/octave