Introduction

ATCA-MF106 Installation and Use (6806800M62B)

38

RmcpPrivLimit = "admin"

RmcpAllowedAuthsCallback = "none md2 md5 straight"

RmcpAllowedAuthsUser = "none md2 md5 straight"

RmcpAllowedAuthsOperator = "none md2 md5 straight"

RmcpAllowedAuthsAdmin = "none md2 md5 straight"

RmcpGuid = "01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16"

RmcpUser2 = "'' '' admin 64 none md2 md5 straight"

RmcpUser3 = "user user admin 64 none"

RmcpUser4 = "kanne kanne admin 64 none md2 md5 straight"

RmcpUser5 = "hf hf admin 64 none md2 md5 straight"

RmcpUser6 = "Administrator Administrator admin 64 none md2 md5 straight"

1.3.3

Software Upgrade Management

The software upgrade module is responsible for the following services:

Upgrade of payload software on the shelf manager

Upgrade of IPMI firmware of intelligent FRUs in the shelf

Universal upload/download of regular files from/to the shelf manager

Before upgrading a particular software component, the new image has to be transferred to the
shelf manager. The software upgrade module requires an external server where the new image
is located. The server location is specified by the URL. The file transfer uses FTP and requires an
external FTP server.

The software upgrade management interface additionally supports a universal upload and
download mechanism. This enables the transfer of any regular files to and from the shelf
manager.

1.3.4

High-Availability Management

High availability management includes redundancy and network management.

1.3.4.1

Redundancy

The redundancy is provided by the shelf managers. The implemented redundancy mechanism
is cold standby. In case of a failure, a failover is performed from the active to the standby shelf