5.2.8.5 CONFIGURATION SETUP screens

Figure 5-22: CONFIGURATION SETUP Menus

The configuration setup screens are not menus but only serve to inform the user of the software options
installed in the AC source. The cursor can be moved to any of the fields in this screen but none of these
fields can be changed. The following information is provided on this screen:

Entry Description

CONFIGURATION SETUP 1

NO. OUTPUT

Displays the phase mode option. SELECT indicates the phase mode
option is installed and the user can select between single and three
phase modes of operation.

FIXED indicates the phase mode option is not installed and only
single phase or three phase mode of operation is possible.

CONFIGURATION SETUP 2

LF

Indicates the presence of the Low Frequency limit option. If this
option is set, the maximum frequency that can be programmed is 500
Hz.

SYSTEM

This field sets the controller for the correct BPS system configuration.
Available settings are:

BPS30-1

Single

phase

BPS30 system Master

BPS30-3

Three phase BPS30 system Master

BPS45-1 Single

phase

BPS45 system Master

BPS45-3

Three phase BPS90 system Master





BPS75-3

Three phase BPS75 system Master

BPS90-3

Three phase BPS90 system Master

BPS150-3

Three phase BPS150 system Master

BPS180-3

Three phase BPS180 system Master

AUX

Three phase Auxiliary System.