2.1.2 Output

Note:

All specifications are for AC unless otherwise indicated.

Output Parameter

BPS30

BPS45

BPS75

BPS90

BPS150

BPS180

Modes:

Single or three phase depending on model.

Voltage:

Ranges (L-N):

AC Mode

Low: 0 - 150 V / High: 0 - 300 V, (0-400V optional)

Resolution:

AC Mode

0.1 V

Accuracy:

± 0.3 V < 100Hz, ± 0.6 V > 100Hz, AC mode

± 1 V DC mode

From 5% V range to 100% of V range, RMS bandwidth < 10KHz

Distortion THD

1

:

(Resistive full load,
normal mode)

< 0.5 % @ 16 - 66 Hz

< 1.00 % @ 66 - 500 Hz

< 1.25 % @ > 500 Hz

Load Regulation:

0.25 % FS @ DC - 100 Hz

0.5 % FS @ > 100 Hz

Line Regulation:

0.1% for 10% input line change

DC Offset Voltage:

< 20 mV

Output Noise:
(20 kHz to 1 MHz)

< 2 V

RMS

low V Range

< 3 V

RMS

high V Range

Output Coupling

AC coupled all voltage ranges.

Power: (total power for all phases, either range, at full scale voltage, maximum ambient T = 35° C)

AC Mode

30 KVA

45 KVA

75 KVA

90 KVA

150 KVA

180 KVA

Current:

Note: Current, maximum amps indicated per phase available between 50 and 100 % of voltage range. Maximum

ambient temperate for full power operation at full-scale voltage is 35° C.

AC

Mode

Single Phase

BPS30-1,
single phase
V Lo: 200A
V Hi: 100A

BPS45-1,
single phase
V Lo: 300A
V Hi: 150A

N/A

N/A

N/A

N/A

AC

Mode

Three Phase

BPS30-3,
per phase
V Lo: 67A
V Hi: 34A

BPS45-3,
per phase
V Lo: 100A
V Hi: 50A

BPS75-3,
per phase
V Lo: 167A
V Hi: 83A

BPS90-3,
per phase
V Lo: 200A
V Hi: 100A

BPS150-3,
per phase
V Lo: 333A
V Hi: 167A

BPS180-3,
per phase
V Lo: 400A
V Hi: 200A

Constant Power Mode:

Operation at higher currents but constant power is possible from 80% of Voltage range (125% of max.
current) declining to 100% of maximum current at 100 % of voltage range for short periods of time or at
reduced ambient temp. (< 15 mins @ 30° C). See Figure 2-1 and Figure 2-4.

Note: Current derates linearly from 50% of voltage range to 20% of specified current at 5% of voltage range

1

The distortion specification for the BPS Series is valid for pure (inductance < 12 uH) resistive load conditions and using a 30

KHz LP filter on distortion meter.