beautypg.com

AMETEK BPS Series User Manual

Page 147

background image

User Manual

AMETEK Programmable Power

BPS Series

147

Number

Message String

Cause

Remedy

DC mode.

-201

"Invalid while in local"

Command issued but unit is
not in remote state

Put instrument in remote state
before issuing GPIB commands.

-203

"Command protected"

Command is locked out

Some commands are supported by
the unit but are locked out for
protection of settings and are not
user accessible.

-210

"Trigger error"

Problem with trigger system.

Unit could not generate trigger for
transient execution or
measurement.

-211

"Trigger ignored"

Trigger request has been
ignored.

Trigger setup incorrect or unit was
not armed when trigger was
received. Check transient system or
measurement trigger system
settings.

-213 "Init

ignored"

Initialization request has been
ignored

Unit was told to go to armed state
but was unable to do so. Could be
caused by incorrect transient
system or measurement acquisition
setup.

-220

"Parameter error"

Parameter not allowed.

Incorrect parameter or parameter
value. Check programming manual
for allowable parameters

-221 "Setting

conflict"

Requested setting conflicts
with other setting in effect.

Check other settings. E.g. trying to
program a DC offset while in AC
mode

-222

"Data out of range"

Parameter data outside of
allowable range.

Check programming manual for
allowable parameter values

-223

"Too much data"

More data received than
expected

Check programming manual for
number of parameters or data block
size

-224

"Illegal parameter value"

Parameter value is not
supported

Check programming manual for
correct parameters

-226

"Lists not same length"

One or more transient lists
programmed has different
length.

All lists must be of same length or
transient cannot be compiled and
executed.

-241

"Hardware missing"

N/A

N/A

-254 "Media

full"

No storage space left to save
settings or data.

Delete other settings or data to
make room.

-255 “Directory

full”

Too many waveform
directory entries

Delete one or more waveforms
from waveform memory to make
room.

-256

“File name not found”

Waveform requested not in
directory

Check waveform directory for
waveform names present.

-257

“File name error”

Incorrect filename

Too many or non ASCII characters
used in waveform file definition.

-283 “Illegal

variable

name”

Variable name illegal.

Use ASCII characters only

-300

"Device specific error"

Hardware related error

Check hardware for proper
operation.

-311 "Memory

error"

Waveform memory checksum
error.

May be the result of incomplete
user-defined waveform download.
Check interface and try