PHASE OFST

IHARM FS

IMP. REAL FS

IMP. REACT FS

IMP. REAL MIN

IMP. REACT MIN

PREVIOUS SCREEN

5.2.4 PROGRAM Menu

Figure 5-8: PROGRAM Menu

The PROGRAM menu is shown in Figure 5-8. It can be reached in one of two ways:

1. by selecting the PROGRAM entry in the MENU screen and pressing the ENTER key

2. by pressing the PROG key in the FUNCTION keypad

The PROGRAM menu is used to change output parameters. The most commonly used parameters are all
located in PROGRAM 1. The PREVIOUS SCREEN entry, when selected, will return the user to the most
recently selected menu. This is normally the MENU screen unless the PROGRAM menu was selected
using the PROG key on the FUNCTION keypad. Less frequently used parameters are located in
PROGRAM 2, which can be reached from the PROGRAM 1 screen using the MORE selection, or by
pressing the PROGRAM key twice.

The following choices are available in the PROGRAM menus:

Entry Description

PROGRAM 1

VOLTAGE

Programs the output voltage in Vrms while in AC mode or absolute
voltage when in DC mode. In DC mode, negative values can be
entered.

FREQ

Programs the output frequency when in AC mode. If the unit is in DC
mode, the value for FREQ will be set to DC and cannot be changed
until AC mode is selected. When in AC mode, the frequency can be
changed from 16 Hz to 500 Hz. Values entered that fall outside this
range will generate a -200 RANGE ERROR and will not be accepted.

VOLT RANGE

Selects 150V, 300V or optional 400V range in AC mode and 200V or
400V range in DC mode. The actual range values may be different
depending on the configuration. The value of this field can only be
changed with the shuttle or the +/- key.

CURR LIMIT

Sets the current limit value for the current detection system. When the
load current value exceeds the set current limit, a fault condition is
generated. The actual response of the AC Source to a current limit
fault is determined by the protection mode selected in the
CONFIGURATION menu. (CC = Constant Current, CV = Constant
Voltage).