beautypg.com

AMETEK BPS Series User Manual

Page 15

background image

AMETEK Programmable Power

BPS Series User Manual M440077-01 Rev A

15




Figure 2-1: Sample BPS90 Voltage / Current Rating Chart for 150/300 V AC Ranges – Derated.



2.1.3 AC Measurements

Listed measurement specifications apply to BPS90 model only. See notes for other models and
configurations.

Parameter

Range

Accuracy (

)

Resolution

Frequency

16.00 - 820.0 Hz

0.01% + 0.01 Hz

0.01 to 81.91 Hz
0.1 to 500 Hz
1 Hz above 500 Hz

RMS Voltage

0 - 300 Volts

0.1% FS, < 100 Hz
0.2% FS, > 100 Hz

0.01 Volt

RMS Current

0 - 250 Amps

0.5% FS, < 100 Hz
1.0% FS, > 100 Hz

0.1 Amp

Peak Current

0 - 750 Amps

2% FS, < 100 Hz
4% FS, > 100 Hz

0.1 Amp

VA Power per
Phase

0 - 30 KVA

1% FS , < 100 Hz
2% FS, > 100 Hz

10 VA

Real Power per
Phase

0 - 30 KW

1% FS, < 100 Hz
2% FS, > 100 Hz

10 W

Power Factor
(>0.2kVA)

0.00 - 1.00

0.01, <100 Hz
0.02, 100-820 Hz

0.01

Note: Accuracy specifications are valid above 100 counts. For current and power measurements, specifications apply
from 2% to 100% of measurement range.

Note: Power factor accuracy applies for PF > 0.5 and VA > 50 % of max.