beautypg.com

Adtec digital DTA-3050 (version 6.02.14) Manual User Manual

Page 44

background image

SDT

Service Description Table;;The Service Description table describes services which are part on an MPEG2 transport stream.

There is one SDT per transport stream.

The SDT may include:

name of the service.

service identifier.

service status.

whether or not the service is scrambled.

The SDT uses the reserved PID 0x0011.

Control

Type

Options

Function

Enable

pull-down menu

Yes
No

Switch table type on or off

Rate

text input box

user-defined

determines how often an SDT will be included in the stream;
measured in tenths of a second

TOT

Local Time Offset Descriptor; allows for local time to be converted from UTC.

Control

Type

Options

Function

Country Code

text field

user-defined

three-letter country designator

Country Time Zone

text field

user-defined

numeric time zone indicator

EIT

Control

Type

Options

Function

Enable

pull-down menu

Yes
No

Switch table type on or off

Rate

text input box

user-defined

determines how often an EIT will be included in the stream;
measured in tenths of a second

39