Output ASI LED- located in "Out" indicator group at left of front panel (Asynchronous Serial Interface)
LED Color
Status
Red
no egress; overflow
Yellow
Outputting Fills (only when 100%; do not flash green and yellow)
Green
Outputting data
Flashing Green
when unit is configured as the back-up
Output SMPTE 310M LED- located in "Out" indicator group at left of front panel
LED Color
Status
Red
no egress; overflow
Yellow
Outputting fills
Green
Outputting data
Clear
not configured
Output CA LED - located in "Out" indicator group at left of front panel (Conditional Access)
LED Color
Status
Yellow
sharing Conditional Access keys
Green
Conditional Access enabled
Unlit
Not enabled
Output GigE LED
Although there is an LED on the panel, it is non-functional.
On the rear
Input LEDs
ASI Inputs 1-10
LED Color
Status
Red
no sync/no tables
Yellow
port enabled, but no programs are mapped to output
Green
OK- normal operation
Green-flashing
port is a backup in a redundant pair