beautypg.com

Input leds – Adtec digital DTA-3050 (version 6.02.14) Manual User Manual

Page 17

background image

Output ASI LED- located in "Out" indicator group at left of front panel (Asynchronous Serial Interface)

LED Color

Status

Red

no egress; overflow

Yellow

Outputting Fills (only when 100%; do not flash green and yellow)

Green

Outputting data

Flashing Green

when unit is configured as the back-up

Output SMPTE 310M LED- located in "Out" indicator group at left of front panel

LED Color

Status

Red

no egress; overflow

Yellow

Outputting fills

Green

Outputting data

Clear

not configured

Output CA LED - located in "Out" indicator group at left of front panel (Conditional Access)

LED Color

Status

Yellow

sharing Conditional Access keys

Green

Conditional Access enabled

Unlit

Not enabled

Output GigE LED

Although there is an LED on the panel, it is non-functional.

On the rear panel, a functional GigE indicator is found. See Rear Panel

Connections in the "Tour the Box" section for a full description.

Input LEDs

ASI Inputs 1-10

LED Color

Status

Red

no sync/no tables

Yellow

port enabled, but no programs are mapped to output

Green

OK- normal operation

Green-flashing

port is a backup in a redundant pair

Getting Started