Adtec digital DTA-3050 (version 6.02.14) Manual User Manual
Page 35
Screenshot- Inputs Level 2: Portion of Window shown
Control
Type
Options
Function
Input State
pull-down menu
Enabled
Disabled
Clear
designates status (role) for this port
Input Mode
pull-down menu
Auto
MHP Injector
SI Injector
Manual
Pass
manual is strongly recommended
Input Tables
pull-down menu
None
MPEG
DCII
DVB
ATSC
specifies table format
Pass CA
pull-down menu
Yes
No
designates if CA programming will be passed on by the
DTA
Redundancy Group
pull-down menu
Inputs 1-10
Disabled
designates an input stream as a backup
Redundancy Role
pull-down menu
Primary
Backup
Disabled
designates the unit as the primary or the backup in a
two-Mux Master/Slave setup
Note: select 'Disabled' if operating the unit as a
stand-alone.
Available Programs and Current Programs
These windows display the available programming coming into the DTA, and programming streaming out. To make an
available program current, highlight it and click
Important: remember to click
User Interface
30