Inputs Screen
The Inputs screen the settings and function of the 10 ASI inputs featured on the DTA3050. For each input, the following is
listed:
Data
Function
State
status of the input; active port, inactive port, or inactive due to stream issue
Format
bytes of incoming data per DVB packet; will display 188 or 204
Mode
type of signal the DTA is passing
Redundancy
this is an on/off indicator signifying whether the feature is enabled/disabled for this input
Data Rate
quantity of data coming in, measured in Mbps
Fill Rate
quantity of fill packets in Mbps
Total Rate
sum of data rate and fill rate
Logged In
When logged into the unit, the Inputs screen offers two levels of access to the unit's programming. The first level looks much