Range
}
Base unit
m1p
}
Terminator
}
Documentation on data medium
Unit features
Using the product
m1p:
Base unit from the configurable control system PNOZmulti
The product has the following features:
}
Can be configured in the PNOZmulti Configurator
}
Positive-guided relay outputs:
– 2 safety outputs
Depending on the application, up to PL e of EN ISO 13849-1 and up to SIL CL 3 of
EN IEC 62061
}
Semiconductor outputs:
– 4 safety outputs
Depending on the application, up to PL e of EN ISO 13849-1 and up to SIL CL 3 of
EN IEC 62061
– 1 output for standard applications
}
4 test pulse outputs
}
1 cascading input and output;
can also be used as a standard output
}
20 inputs for connecting, for example:
– E-STOP pushbuttons
– Two-hand buttons
– Safety gate limit switches
– Start buttons
– Light beam devices
– Scanners
– Enabling switches
– PSEN
– Operating mode selector switches
– Pressure sensitive mats
}
Muting function
}
LED for:
– Diagnostics
– Supply voltage
– Output circuits
– Input circuits
2
2.1