Function description

Integrated protection mechanisms

The relay conforms to the following safety criteria:

}

The circuit is redundant with built-in self-monitoring.

}

The safety function remains effective in the case of a component failure.

}

The relay contacts meet the requirements for safe separation through increased insula-

tion compared with all other circuits in the safety system.

}

The safety outputs are tested periodically using a disconnection test.

Functions

The function of the inputs and outputs on the control system depends on the safety circuit
created using the PNOZmulti Configurator. A chip card is used to download the safety cir-
cuit to the base unit. The base unit has 2 microcontrollers that monitor each other. They
evaluate the input circuits on the base unit and expansion modules and switch the outputs
on the base unit and expansion modules accordingly.
The LEDs on the base unit and expansion modules indicate the status of the configurable
control system PNOZmulti.
The online help on the PNOZmulti Configurator contains descriptions of the operating
modes and all the functions of the control system, plus connection examples.

Block diagram

Interface

fieldbus

,

expansion module

Interface chip card

Ethernet

/

RS 232

Interface

expansion module

O4 O5

A1 A2

I0

I14

I6

I11

I9 I10

I13

I8

I7

I16

I12

I18

I15

I2

I4 I5

I1

I3

I17

I19

Input

Power

Cascading

Test pulse

output

24 V

0 V

24 V

0 V

13

23

CI+ CI- CO+ CO- T0 T1 T2 T3 O0 O1 O2 O3 OA0

14 24

4

4.1

4.2