Display elements for the Ethernet connection (only PNOZ m1p ETH)

The operating and fault states of the Ethernet connection are displayed via the LNK (Link)
and TRF (Traffic) LEDs on the Ethernet interfaces.

LED

Signal

Meaning

LNK

(green)

No network connection

Network connection present

TRF (yel-

low)

No data traffic

Data traffic present

Reset Ethernet connection settings

The Ethernet connection settings of the base unit can be configured in the PNOZmulti Con-
figurator.
You can reset the base unit's Ethernet connection settings to the default settings.
Proceed as follows:

}

Switch off the supply voltage

}

Remove the chip card

}

Restart the base unit without the chip card inserted.

The Ethernet connection settings are now reset to the default settings.