1 safety characteristic data, Safety characteristic data – Pilz PNOZ m1p base unit User Manual
Page 36
Technical Details
Operating Manual PNOZ m1p (ETH)
20878-EN-12
36
Safety characteristic data
Unit
Operating
mode
EN ISO
13849-1: 2006
PL
EN ISO
13849-1: 2006
Category
EN IEC 62061
SIL CL
EN IEC 62061
PFH
D
[1/h]
EN ISO
13849-1: 2006
T
M
[year]
Logic
CPU
–
PL e
Cat. 4
SIL CL 3
4,90E-09
20
Expansion
–
PL e
Cat. 4
SIL CL 3
9,20E-09
20
Input
SC inputs
1-channel
PL d
Cat. 2
SIL CL 2
2,50E-09
20
SC inputs
2-channel
PL e
Cat. 4
SIL CL 3
2,90E-10
20
SC inputs
Short cir-
cuit-forming
safety mats
PL d
Cat. 3
SIL CL 2
1,81E-09
20
SC inputs
1-ch., pulsed
light beam
device
PL e
Cat. 4
SIL CL 3
2,50E-10
20
Cascad. inputs –
PL e
Cat. 4
SIL CL 3
3,10E-10
20
Output
SC outputs
1-channel
PL d
Cat. 2
SIL CL 2
7,00E-09
20
SC outputs
2-channel
PL e
Cat. 4
SIL CL 3
8,60E-10
20
Cascad. out-
puts
–
PL e
Cat. 4
SIL CL 3
4,91E-10
20
Relay outputs
1-channel
PL c
Cat. 1
-
2,90E-08
20
Relay outputs
2-channel
PL e
Cat. 4
SIL CL 3
3,00E-10
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
Information
A safety function's SIL/PL values are
not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
ATTENTION!
It is essential to consider the relay's service life graphs. The relay outputs'
safety-related characteristic data is only valid if the values in the service life
graphs are met.
The PFH value depends on the switching frequency and the load on the relay output. If the
service life graphs are not accessible, the stated PFH value can be used irrespective of the
switching frequency and the load, as the PFH value already considers the relay's B10d val-
ue as well as the failure rates of the other components.
8.1