beautypg.com

2 dimensions, 3 install base unit without expansion module, 4 connecting the base unit and expansion modules – Pilz PNOZ m1p base unit User Manual

Page 15: Dimensions, Install base unit without expansion module, Connecting the base unit and expansion modules

background image

Installation

Operating Manual PNOZ m1p (ETH)
20878-EN-12

15

Dimensions

94 (3.70")

121 (4.76")

135 (5.31")

Install base unit without expansion module

}

The terminator must be fitted to the side of the base unit marked “Termination/Link”.

}

Do not fit a terminator on the left hand side of the base unit.

Terminator

Termination/Link

Connecting the base unit and expansion modules

The modules are linked via jumpers.
There are 2 pin connectors on the rear of the base unit.
A max. of 12 expansion modules plus one fieldbus module may be connected to one base
unit.

}

Ensure that no terminator is connected.

}

Connect the base unit, the expansion modules and the fieldbus module using the jump-

ers supplied.

}

The terminator must be fitted to the last expansion module to the right of the base unit.

}

A terminator must not be fitted to the last expansion module to the left of the base unit.

5.2

5.3

5.4