Technical Details
Operating Manual PNOZ m1p (ETH)
20878-EN-12
33
Environmental data 773100
773103
773104
773105
Climatic suitability
In accordance
with the standard
EN 60068-2-30, EN
60068-2-78
EN 60068-2-30, EN
60068-2-78
EN 60068-2-30, EN
60068-2-78
EN 60068-2-30, EN
60068-2-78
Humidity
93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation
Not permitted
Not permitted
Short-term (only
with protective ex-
tra low voltage)
Short-term (only
with protective ex-
tra low voltage)
EMC
EN 61131-2
EN 61131-2
EN 61131-2
EN 61131-2
Vibration
In accordance
with the standard
EN 60068-2-6
EN 60068-2-6
EN 60068-2-6
EN 60068-2-6
Frequency
10,0 - 150,0 Hz
10,0 - 150,0 Hz
5,0 - 500,0 Hz
5,0 - 500,0 Hz
Max. acceleration
1g
1g
1g
1g
Broadband noise
In accordance
with the standard
–
–
EN 60068-2-64
EN 60068-2-64
Frequency
–
–
5 - 500 Hz
5 - 500 Hz
Max. acceleration –
–
19 m/s² rms
19 m/s² rms
Corrosive gas check
SO2: concentra-
tion 10 ppm, du-
ration 10 days,
passive
–
–
DIN V 40046-36
DIN V 40046-36
H2S: concentra-
tion 1 ppm, dura-
tion 10 days, pas-
sive
–
–
DIN V 40046-37
DIN V 40046-37
Shock stress
In accordance
with the standard
EN 60068-2-27
EN 60068-2-27
EN 60068-2-27
EN 60068-2-27
Acceleration
15g
15g
15g
15g
Duration
11 ms
11 ms
11 ms
11 ms
Max. operating
height above sea
level
2000 m
2000 m
2000 m
2000 m
Airgap creepage
In accordance
with the standard
EN 61131-2
EN 61131-2
EN 61131-2
EN 61131-2
Overvoltage cate-
gory
III
III
III
III
Pollution degree
2
2
2
2
Rated insulation volt-
age
250 V
250 V
250 V
250 V
Rated impulse with-
stand voltage
6,00 kV
6,00 kV
6,00 kV
6,00 kV