StorCase Technology InfoStation 12-Bay 4U Ultra320/SATA User Manual
Page 96
InfoStation 12-Bay RAID User's Guide - Rev. D00
StorCase Technology, Inc.
RAID Controller Configuration
83
RAID Functions Menu
6.1 Init Parity
This function enables the user to initialize an existing RAID 3, RAID 5, RAID 30, or RAID 50 array.
Select either Array 1, 2, 3, 4, 5, 6, 7, or 8 and then either Stop (default) or Start.
6.2 Parity Check
This function enables the user to check an existing RAID 3, RAID 5, RAID 30, or RAID 50 array
for errors.
Select either Array 1, 2, 3, 4, 5, 6, 7, or 8 and then either Stop (default) or Start.
6.3 Beeper
Select either Clear, Enable (default), or Disable. Clear is used to stop a sounding beeper.
6.4 Stop Modem
Select either No (default) or Yes. Select Yes to halt the transmission of subsequent alert
pager/Fax messages once the message has been received and acknowledged.
6.5 Add Disk
NOTE:
Add disk(s) to an existing configuration while the RAID controller is online.
Select disk number (1-12).
6.6 Remove Disk
NOTE:
Remove disk(s) from an existing configuration while the RAID controller is on-
line.
Select disk number (1-12). This function enables the user to shutdown a potentially faulty disk.
If a spare disk is available, it will automatically be added (default = None).