beautypg.com

Lun mapping – StorCase Technology InfoStation 12-Bay 4U Ultra320/SATA User Manual

Page 73

background image

60

RAID Controller Configuration

StorCase Technology, Inc.

InfoStation 12-Bay RAID User's Guide - Rev. D00

LUN Mapping

NOTE:

Refer to sections "2 SCSI Params" and "5 NVRAM" of this User's Guide for further
information.

1.

After the array and partitions have been created, each partition needs to be as-
signed a LUN and mapped to the appropriate SCSI Channel.

2.

Press to invoke the Password screen.

3.

Enter password (default password = 00000000).

4.

Select 2 SCSI Params and press .

a.

Select the SCSI channel your host server is connected to (Primary or Sec-
ondary SCSI) and press .

b.

Select 2.1.4 LUN MAP and press .

c.

Starting with LUN 0, assign one LUN number to each partition (slice) of each
array.

Select LUN number and press .

d.

After selecting LUN number, select the array the partition is in and press
.

e.

Select the partition (slice) you would like to assign this LUN number to and
press .

Slices always start with “00” and increase sequentially according to the
number of partitions that have been created.

5.

Press four times to return to the Main Menu.

6.

Arrow down and select 5 NVRAM. Press .

7.

Select 5.1 Update NVRAM and press .

Select Yes and press .

8.

Select 5.3 Restart and press .

Select Yes and press .

9.

Controller will now reboot (LUN will be mapped upon reboot).

This manual is related to the following products: