beautypg.com

Remote terminal problems, Alert message problems – StorCase Technology InfoStation 12-Bay 4U Ultra320/SATA User Manual

Page 121

background image

108

Appendix C - Troubleshooting

StorCase Technology, Inc.

InfoStation 12-Bay RAID User's Guide - Rev. D00

Remote Terminal Problems

Unable to access the Configuration Mode using the remote terminal (Monitor

Utility).

Cause - The terminal communication settings might not match the settings of the RAID

Controller.

Fix -

Verify that the terminal communication settings of the remote terminal and the RAID
Controller match. Default settings for the RS-232 port is 19200 Baud, 8 Data Bits,
1 Stop Bit, and NO Parity.

Alert Message Problems

Unable to send a Page or FAX using the MODEM port.

Cause - The Page and FAX options might not be enabled, or the default modem initialization

string may not be compatible with your modem.

Fix -

Verify that the Page and FAX options are enabled. Change the modem initialization
string to match your modem (refer to your modem manufacturer's documention for
further information).

The following modem models require their own initialization strings:

Modem Model

Initialization String

Baud Rate

FAX Class

Motorola

ModemSURFR

V.34 28.8

Multitech

Multimodem

2834ZDX
Hayes

Accura 288

V.34 + FAX

Practical Peripherals

PM144MT II

GVC

F-1128V/T2

US Robotics

Sportster 28800

AT&D\Q1E

AT&D0&E5E0

AT&D0&K4E0

AT&K4

AT&D0&B1&H2

AT&H2&I1&R1&B1

Up to 38400

Up to 38400

38400 only

Up to 38400

38400 only

38400 only

1 & 2

2 only

1 & 2

2 only

1 & 2

1 only