74

RAID Controller Configuration

StorCase Technology, Inc.

InfoStation 12-Bay RAID User's Guide - Rev. D00

Terminal Port Menu

NOTES:

The RAID controller's terminal port settings must match the settings of the re-
mote terminal on the host.

Flow control should be set to "NONE" on the host terminal (refer to section
"RAID Management Connection Setup" and Table 1 for further information).

3.2 Terminal Port

This function enables the user to set the Baud Rate, Stop Bit, Data Bit, and Parity parameters
for the terminal port to match those of the host.

3.2.1 Baud Rate

Select either 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, or 115200 (default).

3.2.2 Stop Bit

Select either 1 (default) or 2.

3.2.3 Data Bit

Select either 7 or 8 (default).

3.2.4 Parity

Select either None (default), Odd, or Even.