102
Appendix C - Troubleshooting
StorCase Technology, Inc.
InfoStation 10-Bay RAID User's Guide - Rev. E00
Error Message
Description
Do_IDE_Cmd: wait DRQ
The IDE interface is waiting for DRQ signal to go off in command
phase.
Do_IDE_Cmd:
ERROR (a)!
An error (a) occurred in IDE interface. Use Disk Check to identify
faulty disk channel.
IDE_ISR:
wait Master Int
IDE interface is waiting for an interupt from a disk.
IDE_ISR:
wait IDE Busy off
IDE interface is waiting for disk to be free.
IDE_ISR: Status (a)
IDE disk drive current status (a).
IDE_ISR: wait DRQ
Waiting for disk drive to turn off DRQ in Interrupt phase.
IDE_ISR: DRQ ON
Indicates DRQ is not free in Interrupt phase.
DISK: status (a),
ERROR (b)!
Status (a) and error (b) returned by the disk based on ATA-2
Specification.
DISK: #x
type=a, blkno=b, resid=c
Disk (x) failed to respond to a request by the controller (a).
Block number (b) where the request failed and remaining sectors (c).
DISK: Initialize #x
ERROR!
Disk (x) was unable to be initialized by the controller. Possible
bad disk.
DISK: Initialize #x is
offline!
Disk (x) failed and was removed from the RAID configuration.
DISK: #x not installed!
Disk (x) is not detected by the controller. Possible bad disk.
DISK: #x ERROR
status (a)!
Disk (x) caused an error. The status (a) returned by the disk per
ATA-2 Specification.
ERROR: Not a
hard disk!
Controller does not recognize the device installed.
ERROR: Disk
parameters ERROR!
Controller was unable to read the disk parameters (cylinder, heads,
sectors, multi-sector). Possible bad disk.
ERROR: No
multi-sector mode!
Disk does not support the ATA-2 multi-sector transfer function.
Disk is an older IDE disk.
ERROR: IORDY
not supported!
Disk does not support the ATA-2 multi-sector transfer function.
Disk is an older IDE disk.
DISK: #(a) Remap
area overflow!
The area used to re-map bad sectors is full.
DISK: #(a) Blk no:(b)
is re-mapped
Block number (b)is detected as a bad sector and has been
re-mapped.
DISK: #(a) Blk no:(b)
is re-mapped
No re-map sectors are available while the controller detected bad
sectors.
Table C-1: Error Messages (cont'd)