4.26
Continuous mode at various speeds between the low and high speeds. For each speed, press the Top
Stop key and verify that the press stops within a few degrees of top for each speed.
Section 4.2.4 Operator Terminal Configuration
Section 4.2.4.1 Top Area (Screen) Display Configuration
Pressing the OPERATOR TERMINAL softkey on the Main Configuration menu causes the Top
Display Area Configuration Screen shown in Figure 4.13 to be displayed.
Figure 4.13 Top Display (Screen) Area Configuration.
The OmniLink II LCD Operator Terminal provides for some user customization of the information
displayed in the top areas of the screen to the right of the angle display. When any of the items beside
Area 1, Area 2, etc. at the top of the screen are highlighted pressing the change setting softkey will cause
a box to appear listing all items not already currently assigned to another area. Select the desired
item and press the ENT(ER) key. The currently available items are:
1. Drive Speed. Speed at which a variable speed drive will cause the press to stroke when the clutch is
engaged -- requires optional Analog Input/Output Card for the R/D-Brake Monitor Module
2. Stroking Speed. Actual crankshaft SPM -- available only when the press is actually stroking
3. Auto Press Speed. Drive speed when press is not stroking and crankshaft speed when the press
is stroking-- requires optional Analog Input/Output Card for the R/D-Brake Monitor Module
4. System Status. Diagnostic messages that indicate anything that prevents the start of stroking
5. Reason for the Last Stop. Diagnostic message that gives the reason for the last stop
6. Total Tonnage. If the system is equipped with optional Tonnage & Signature monitor
Stroke
Mode
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
SYSTEM STATUS
Counter OFF
8
0
OK
Top Disp
Config
CHANGE
SETTING
EXIT
AUXILIARY
COMM SETUP
ACCESS
CONFIG
ZERO
STROKE
COUNT
Top Display Area Configuration
When in a Setup Mode
(Inch, Timed Inch, Etc. )
When in a Production Mode
(Single Stroke, Cont. , Etc. )
Area 1 :
Area 2 :
Area 3 :
Area 4 :
Drive Speed
Stroking Speed
Shut Height
System Status
Area 1 :
Area 2 :
Area 3 :
Area 4 :
Drive Speed
Stroking Speed
Order Counter
System Status
Date :
Time :
4/24/2002
10:20:46 AM
Rod/Stroke Units :
Rod Length :
Stroke Length :
in
0.000 in
0.000 in
Default Language :
English