3.12
module) and a group of eight channels for that module. One module may have up to 16 channels. The
PREVIOUS PAGE softkey will appear above the NEXT PAGE softkey only after the NEXT PAGE
softkey is used to select a group of eight other than those shown on the first page. Use the Up/Down
arrow keys to move the cursor (highlight) to a channel whose settings are to be changed. In the figure
above, channel 5 on die protection module 1 is selected. Press the upper right softkey (CHANNEL
SETTINGS). This will take you to the Die Protection Settings screen for channel 1, module 5, shown in
Figure 3.10.
Figure 3.10 Die Protection Channel Settings Screen
Note that the Die Protection Channel Settings screen is channel specific, i.e., since channel 5 of die
protection module 1 was selected when the CHANNEL SETTINGS softkey was pressed in Figure 3.1,
the Die Protection Configuration screen that appears will allow you to settings for this particular
channel. The upper right softkey is now labeled SUPPLY ACCESS CODE. Pressing this softkey will
cause a popup table to appear listing user names as shown in Figure 3.11.
When the user name is selected in the screen shown in figure 3.11, the user name code entry box will
appear as shown in Figure 3.12. Use the number keys on the Operator Terminal keypad to input the
code associated with the user name and press the ENTER key.
Stroke
Mode
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
SYSTEM STATUS
Counter OFF
Die
Protection
SUPPLY
ACCESS
CODE
CHANNEL
DIAGS
NEXT
CHANNEL
0
0
OK
TOP
EXIT
0
90
270
180
Die Prot. Channel Configuration
Module: 1 Channel: 5
Channel Type:
Description:
Input Type:
Stop Type:
Bypassed:
Delay Time:
Delay Strokes:
Window On:
Window Off:
Cyclic
Left Front Stripper
Normally OFF
Top Stop
No
0 msecs
0 Strokes
154
0
213
0
Help
Sets the type of Logic
to apply to the
channel
Cyclic - Norm. OFF
Used to monitor events that occur
once per machine cycle. The input
must be ON somewhere in the timing
window AND OFF somewhere in the
timing window.
PREVIOUS
CHANNEL
DECREMENT
ON ANGLE
INCREMENT
ON ANGLE
DECREMENT
OFF ANGLE
INCREMENT
OFF ANGLE
SoftKey
Press the
SUPPLY
ACCESS CODE