LINK Systems OmniLink II Press Automation Control User Manual
Page 139
August 30, 2002 Manual Version 1.0
7.2
PARAMETER SPECIFICATION
5100-5B Module
Dimensions without
Enclosure
10.4” (264 mm) High x 5.5” (138 mm) Wide x 4.8” (122 mm) Deep
5100-5B Module
Mounting Footprint
without Enclosure
9.77” (248 mm) High x 4.75” (121 mm) Wide
5100-5B Module Single
Enclosure Dimensions
13.3” (338 mm) High x 7” (159 mm) Wide x 5” (203 mm) Deep
5100-5B Module Single
Enclosure Mounting
Footprint
13.75” (249 mm) High x 4.75” (121 mm) Wide
Input Power
100 to 135 VAC @ .5 Amps
Input Fuse Type
Littlefuse 217.500
Electromechanical Relay
240 VAC Max, 30 VDC Max, 5 Amp Max
Electromechanical Relay
Fuse
Littlefuse M251007, Gould GSRV7
Solid State AC Relay
24 - 280 VAC, 3 Amp Max at 45º Ambient, 2 Amp Max @ 70º Ambient
Solid State DC Relay
60 VDC max, 3 Amp Max at 45º Ambient, 2 Amp Max @ 70º Ambient
Solid State AC or DC
Relay Fuse
Littlefuse M251 007, Gould GSRV7
Table 7.1 Specifications
Section 7.3 Mounting
The PLS/Logic module can be mounted in any convenient location. It can be mounted in or near the
OmniLink II Operator Terminal or it can be mounted near the devices that it is controlling. The module
comes in an open frame unit as shown in Figure 7.1, or in an enclosure as shown in Figure 7.2. After
wiring and initial set-up, there is normally no need to access the unit. However, it is suggested that the
unit be mounted in a location that is free of excessive oil and lubricant spray, and that is not subject of
severe shock or vibration.