Lan collision threshold fields – Carrier Access CMG Router User Manual
Page 124
![background image](/manuals/71281/124/background.png)
4-38
CMG Router - Release 2.7
Profile Directory:Local Profile
LAN Collision Threshold
LAN Collision Threshold Fields
LAN
Will indicate if the LAN is UP or Down (DWN).
Collisions
The number of collisions that have occurred during the defined sample interval.
Alarm
This field indicates if there is/is not an active collision alarm.
Sample Interval
Use the Collision Sample Interval in seconds. Range is 0-65536 seconds, default is 10 and
0 = disable.
Collision Hi Threshold
Use this field to set the number of collisions in Interval to raise an alarm. When the number of
collisions rises above the defined number per interval, the alarm will be activated. The default
is 500.
Collision Lo Threshold
Use this field to set the number of collisions in Interval to Clear Alarm. If the number of
collisions drops below the defined number per interval, the alarm will clear. Default is 10.