Form I-VR, P/N 205202 R13, Page 38
First, remove these two
screws.
Then, supporting the
front of the burner,
remove the brass nut at
the other end.
Remove burner.
Brass Nut
FIGURE 36A - Open the
Burner Compartment and
Remove the Burner
R
The spark electrode assembly performs several necessary functions, and
to ensure reliable service, it must be cleaned periodically. The required fre-
quency of cleaning will vary depending on the installation site and the hours of
operation. No less than annual cleaning is recommended.
One of the most important reasons for cleaning the spark electrode assembly
is that the DC current needed to prove the burner must flow through the elec-
trode. That current can either be retarded or totally blocked by deposits and/or
corrosion on the electrode.
Instructions for Removing and Cleaning the Spark Electrode Assembly
(requires phillips screwdriver, 1/4” nut driver, and emery cloth):
1) Turn off or disconnect the main electric supply.
2) Open the control access panel. Rotate the knob on the gas valve to the
“OFF” position. At the ignition controller, disconnect the high voltage spark
electrode wire.
3) Open the burner access panel. Remove the screws and the spark
electrode assembly (Refer to
FIGURES 37A and 37B).
4) Use an emery cloth to clean the two metal rods on the spark electrode.
Clean until they are bright. Wipe off the ceramic insulator.
5) The spark gap must be maintained to 1/8” as illustrated in
FIGURE 37C.
6) Re-assemble, reversing above procedure. Test the heater for proper
operation.
9.2.9 Spark
Electrode Assembly
CAUTION: Due to
high voltage on
the spark wire and
electrode, do not
touch when ener-
gized. See Hazard
Levels, page 2.
FIGURE 36B -
Burner Removed for
Cleaning
9.2.8 Main Burner (cont’d)
9. Maintenance
(cont’d)
9.2 Maintenance Procedures (cont’d)
6) Inspect the cleaned burner for any damage or
deterioration. If the burner has any damage
or signs of deterioration, replace it. Carefully
reverse the above procedures to re-install or
replace the burner.
Test the heater for proper operation.