Form I-OPT-C, P/N 132900 R17, Page 9

A

B

B

C

D

E

D

F

D

E

A

A

B

B

Install D and E

(See NOTE)

Install F

(See NOTE)

B

A

D

F

B

G

Install

G

FIGURE 3C - Install

Supply Duct Partition (

D

),

Bottom (

E

), Bottom Liner

(

F

), and Air Baffle (

G

)

6. Install supply air duct partition (

Code H

) and return air duct partition

(

Code

J

) using sheetmetal screws. (See

FIGURE 3D).

a) Position partition (

Code H

) in the orientation illustrated. Align

the holes and attach the partition to curb sides (

B & B) and

bottom liner (

F).

b) Position partition (

Code J

) in the orientation illustrated. Align

the holes and attach the partition to curb sides (

B & B) and

bottom liner (

F).

7. Install supply air and return duct dividers (

Code K

) and (

Code L

);

divider liners (

Code M

)

and (

Code N

); and duct tops (

Code P

) and

(

Code Q

)

using sheetmetal screws. (See

FIGURE 3E).

a) Position and attach duct dividers (

Codes K & L

) as illustrated.

Cover the insulation with liners (

Codes M & N

) and attach with

screws.

b) Position tops (

Codes P & Q

) with insulation side up. Align the

holes (push the insulation out of the way) and attach the perimeter.

8. Install field-supplied flashing (FIGURE 3B, page 8).

Insulation NOTE: There is no exposed

insulation in the ducts. All insulation in air-

flow paths is covered with a liner.

A

B

B

D

F

C

H

F

C

B

B

J

J

G

B

M

N

P

Q

K

L

B

L

K

C

C

And

corresponding

liners (M & N).

Install duct

tops (P

& Q).

(insulation

side)

B

B

Install

insulated

dividers

(K & L)

9. Before placing the MAPS

®

unit or optional duct furnace on the curb:

ID

P/N by Cabinet Size

D

A-261658

B-261659

C-261673

E

A-261660

B-261661

C-261674 & 261428

F

A-261394

B-261395

C-261418 & 261429

G

A-268604

B-268605

C-268606

NOTE: Cabinet C - Insulated

Bottom (Code E) and Bottom

Liner (Code F) are two piece

ID

P/N by Cabinet Size

H

A-261396 B-261397 C-261419

J

A-261662 B-261663 C-261675

ID

P/N by Cabinet Size

K

A&B-261666

C-261677

L

A-261667 B-261668 C-261678

M

A-261408 B-261409 C-261426

N

A&B-261405

C-261424

P

A-261664 B-261665 C-261676

Q

A&B-261669

C-261679

Apply 1/4" x 1-1/4" foam sealant tape to both the top surface of the curb rails and the top surface of the perimeter of the duct

dividers, being sure to make good butt joints at all corners.

If installing an optional duct furnace curb section (Option JH), place it on the curb before the unit. Follow the instructions in the

system installation manual.

When it is time to lift the MAPS

®

unit or optional duct furnace onto the prepared curb (See Rigging and Lifting in the

unit installation manual, Form I-MAPS III&IV), be sure that all of the above preparations have been made.

IMPORTANT:

Verify that the unit will be placed in the correct airflow orientation to mate properly with the discharge and return air openings.

Remember that the INLET AIR END OF THE UNIT is at the DISCHARGE (duct connection) END OF THE CURB.

FIGURE 3D - Install the Large Duct

Partitions

(

H&J

)

FIGURE 3E - Install Smaller

Duct Partitions and Liners (

K,

L, M, N

) and Duct Tops (

P&Q

)