Candle KLVHSKONCT GC32-9172-00 User Manual
Page 448

448
Candle Products Messages Manual (KLVHS–KONCT)
System Programmer Response:No
KOCJO001
INITIALIZE COMPLETED NORMALLY.
Explanation: This facility has initialized successfully.
System Action: Processing continues normally.
User Response: None.
Message Type:
Confirmation.
KOCJO002
INTERFACE SHUTDOWN REQUESTED.
Explanation: A request to shut down is being processed.
System Action: The facility terminates all processing.
User Response: None.
Message Type:
Confirmation.
KOCJO003
INTERFACE SHUTDOWN COMPLETED.
Explanation: This facility was in a suspended state when a shutdown was
requested. The shutdown request has completed termination of this facility.
System Action: All processing is terminated.
User Response: None.
Message Type:
Confirmation.
KOCJO004
INTERFACE SUSPEND REQUESTED.
Explanation: A request to suspend the facility is being processed.
System Action: The facility disables operations and returns to a suspended
state.
User Response: None.
Message Type:
Confirmation.
KOCJO005
INTERFACE INITIALIZED STATUS: SUSPENDED.
Explanation: This facility has partially initialized to a suspended state.
System Action: The facility remains in a suspended state until a resume
request is processed.
User Response: None.
Message Type:
Confirmation.
KOCJO006
INTERFACE RESUMED SUCCESSFULLY.
Explanation: A request to resume operations has been processed.
System Action: The facility is now fully initialized and continues processing
normally.
User Response: None.
Message Type:
Confirmation.
KOCJO007
ASSEMBLED AGAINST DIFFERENT CICS RELEASE.
Explanation: Initialization failed because the facility determined that it was not
assembled using the correct CICS macro libraries.
System Action: Processing terminates.
User Response: Assemble the facility using the correct CICS macro libraries.
Message Type:
User error.