Candle KLVHSKONCT GC32-9172-00 User Manual
Page 122

122
Candle Products Messages Manual (KLVHS–KONCT)
KLVVP013
"TAG" MAY ONLY BE SPECIFIED IN THE VM VERSION OF THE
PRODUCT
Explanation: "TAG" is not a valid VPRINTER parameter for the MVS version of
the product.
System Action: The command is rejected and the VPRINTER is not started.
User Response: Review the command and reissue.
Message Type:
ERROR.
KLVVP014
FFEED OPTION -xxxxxxxx- INVALID
Explanation: The specified formfeed option is invalid.
System Action: The command is rejected and the VPRINTER is not started.
User Response: Review the command and reissue.
Message Type:
ERROR.
KLVVP015
MAXLINE PARAMETER NOT IN RANGE(1–255)
Explanation: The line length for SYSOUT data must be 1–255 characters.
System Action: The command is rejected and the VPRINTER is not started.
User Response: Specify a MAXLINE value between 1–255.
Message Type:
ERROR.
KLVVP016
SYSOUT MUST BE SPECIFIED WITH THE FOLLOWING OPTIONS:
FFEED(IF)-, FFEED(FIRST)-, FFEED(NONE), IGNEOM-, XSEGLINE-,
NOTRUNC-.
Explanation: A VPRINTER option only valid for a SYSOUT VPRINTER was
specified for a VPRINTER that was not a SYSOUT VPRINTER.
System Action: The command is rejected and the VPRINTER is not started.
User Response: Review the command and reissue.
Message Type:
ERROR.
KLVVP017
UNABLE TO ALLOCATE VPRINTER ACB: APPLID(appl)
Explanation: CT/Engine was unable to allocate the appl specified in the
VPRINTER command.
System Action: The command fails and the VPRINTER is not started.
User Response: Contact Candle Customer Support.
Message Type:
ERROR.
KLVVP018
UNABLE TO OPEN VPRINTER ACB: APPLID(appl) REASON (rc)
Explanation: CT/Engine was unable to OPEN the appl specified in the
VPRINTER.
System Action: The command fails and the VPRINTER is not started.
User Response: The REASON field contains the return code rc from the
ACF/VTAM OPEN macro instruction. Refer to the IBM manual ACF/VTAM
Programming
to determine the cause of the error.
Message Type:
ERROR.