Candle KLVHSKONCT GC32-9172-00 User Manual
Page 314

314
Candle Products Messages Manual (KLVHS–KONCT)
KN3AF060
VSAM LOGGING DISABLED — MODULE(error_module) REASON
(cccccccc)
Explanation: VSAM logging is disabled and the reason for it is cccccccc. This
message is usually accompanied by other messages in RKLVLOG. Following is
the list of possible reasons:.
System Action: VSAM logging is disabled.
User Response: Check for accompanying messages for any of the following
reasons:.
Message Type:
Warning.
KN3AF061
ERROR WHEN READING FROM DSN(dsname) — MODULE(error_module)
Explanation: An error occurred when reading from a VSAM cluster named
dsname
. This indicates a DASD problem.
System Action: None.
User Response: Check for any accompanying messages in RKLVLOG and
respond according to those messages.
Message Type:
Warning.
KN3AF062
PUT FAILED FOR REASON OTHER THAN EOF FOR DSN(dsname) —
MODULE(error_module) FDBWD(fdbwd)
Explanation: OMEGAMON II for VTAM encountered an error while writing an
exception or interval record to the cluster dsname.
System Action: None.
User Response: Check for any accompanying messages in RKLVLOG and
respond according to those messages.
Message Type:
Warning.
LOAD
Some modules are missing.
ALLOC
Error during VSAM dataset allocation.
INIT
Error during initial load to VSAM cluster.
PUT
Error during VSAM PUT. Probable DASD problem.
INTERNAL
Internal error.
ABEND
Abend occurred during logging to VSAM cluster.
VSAMSERV
Internal VSAM services are unavailable.
LOAD
Check installation.
ALLOC
Check installation.
PUT, INIT
Check for DASD problem.
INTERNAL,
ABEND
Contact
Candle Support Services.
VSAMSERV
Check to make sure that termination was requested. If it was not,
gather the preceding 30 minutes of the RKLVLOG and any dumps
that were produced or taken, and contact Candle Support
Services.