Candle KLVHSKONCT GC32-9172-00 User Manual
Page 216

216
Candle Products Messages Manual (KLVHS–KONCT)
KMC0374E
Invalid channel name:
%s
.
Explanation: The channel name @2 that you specified for this object is not a
valid MQSeries channel name.
User Response: Ensure that the channel name is valid. The character set that
can be used for naming MQSeries channels is as follows:
®
Uppercase A-Z
®
Lowercase a-z (however, on systems using EBCDIC Katakana you cannot use
lowercase characters, and there are also restrictions on the use of lowercase
letters for OS/390 console support).
®
Numerics 0-9
®
Period (.)
®
Forward slash (/)
®
Underscore (_)
®
Percent sign (%). The percent sign (%) is a special character to RACF®. If you
are using RACF as the external security manager for MQSeries for OS/390,
you should not use % in object names. If you do, these names are not
included in any security checks when RACF generic profiles are used.
KMC0375E
Invalid maximum message length:
%s
.
Explanation: The maximum message length specified is not valid.
User Response: Correct the maximum message length. On AIX, HP-UX, OS/2
Warp, Sun Solaris, and Windows NT, specify a value greater than or equal to zero,
and less than or equal to the maximum message length for the Queue Manager.
On other platforms, specify a value greater than or equal to zero, and less than or
equal to 4 MB, or 4,194,304 bytes.
KMC0376E
Invalid queue depth threshold:
%s
.
Explanation: You specified an invalid queue depth threshold for the queue.
User Response: Specify a valid queue depth threshold. The value is expressed
as a percentage of the maximum queue depth, and must be greater than or equal
to zero, and less than or equal to 100.
KMC0377E
Invalid service interval:
%s
.
Explanation: You specified an invalid service interval milliseconds property for
the queue.
User Response: Specify a valid service interval milliseconds property.
KMC0379E
Invalid maximum queue depth:
%s
.
Explanation: You specified an invalid maximum queue depth for the queue.
User Response: Specify a valid maximum queue depth. Specify a value
greater than or equal to zero, and less than or equal to:
®
999,999,999 if the queue is on MVS/ESA.
®
640 000 if the queue is on any other MQSeries platform.