Power:

user interface

control module

supplied from the control module.

115... 230 VAC (±15%), 50/60 Hz

(±3 Hz), 10 VA max.

Rated impulse voltage:

4 KV.

Overvoltage category:

III.

Class and structure of software:

A.

Clock:

incorporated.

Autonomy in the event of a power-cut: 24 h with fully charged.

Battery charging time: 2 min (the battery is charged by the device power

supply).

Analogue inputs:

3 inputs (environment probe, needle probe and steam reduction probe), can be

set via configuration parameter for J/K thermocouples or

Pt 100 2 wire probes.

thermocouple J type analogue inputs

Type of sensor:

iron/constantan.

Field of measurement: from -50 to 700°C (from -58 to 1,292 °C).

Resolution:

1 °C (1 °F).

Protection:

none.

thermocouple K type analogue inputs

Type of sensor:

chromel/alumel.

Field of measurement: from -50 to 1,100°C (from -58 to 2,012 °C).

Resolution:

1 °C (1 °F).

Protection:

none.

Pt 100 analogue inputs

Type of sensor:

Pt 100 class A.

Field of measurement: from -50 to 550°C (from -58 to 1,022 °C).

Resolution:

1 °C (1 °F).

Protection:

none.

Digital inputs:

5 inputs:

4 inputs (door micro switch, fan circuit breaker protection on/stand-by and

electric absorption protection), which can be set via configuration

parameter due to normally open contact/normally closed contact

(potential-free contact, 5 VDC, 0.5 mA)

-

1 (fan circuit breaker protection) which can be set via configuration

parameter due to normally open contact/normally closed contact

(live contact, 115... 230 VAC)