5

COMMISSIONING

5.1

Commissioning

Operate as indicated:

1.

Install the device using the methods illustrated in the 2 “DIMENSIONS AND INSTALLATION” chapter, following all warnings

given in the 2.5 “Installation warnings” paragraph.

2.

Connect the device electrically using the methods illustrated in the 3 “ELECTRIC CONNECTION” chapter, following all

warnings given in the 3.2 “Warnings for the electric connection” paragraph, without connecting the power supply and the

mains electricity.

3.

Connect the device power supply: a splash screen will be displayed for a few seconds.

4.

Set the time, the date and the day of the week; see paragraph 14.1 “Setting the time, date and day of the week”.

5.

Configure the device with the procedure illustrated in the paragraph 14.2 “Setting the configuration parameters”.

The following table illustrates the meaning of the configuration parameters; the parameters are listed with the order,

according to which, it is appropriate that the device is configured.

PARAM.

MEANING

FACTORY SETTING

P0

probe type

0 = thermocouple

J

1 = thermocouple

K

2 = Pt 100 2 wires

0

P1

unit of measurement

0 =

°C

1 =

°F

0

P2

enabling the needle probe

1 =

YES

0

F0

type of fan management

0 = in “on/off” mode and at single speed

1 = in “on/off” mode, with single speed and with inversion of the direction of

rotation of the fan

2 = in “on/off” mode, with dual speed and with inversion of the direction of

rotation of the fan

3 = in modulating mode and with inversion of the direction of rotation of the

fan

0

t0

steam generation mode

0 = direct

1 = with an external humidifier

2 = combined (i.e. direct and with external humidifier)

0

u0

type of vent output contact

0 = normally open (vent open with closed contact)

1 = normally closed (vent open with open contact)

0

u1

utility managed by the vent output

0 = ELECTROVALVE

ON/OFF

1 = MOTORISED

ELECTROVALVE - in this case the u2, u3 and u4 parameters

will assume significance

0