EVCO S.p.A.

Vcolor 338 S | Installer manual ver. 1.2 | Code 144VC338SE124

page 43 of 50

No connection

ALARM

user interface-control module communication alarm

solutions:

-

check user interface-control module control module

main consequences:

-

if the alarm occurs when the device is on, a cooking cycle cannot be started

-

if the alarm occurs during an cooking cycle, no consequence

Temperature

ALARM

maximum temperature alarm

solutions:

-

check the temperature detected by the environment probe; see parameters A0, A1 and A3

main consequences:

- no

consequence

Board

temperature

alarm

ALARM

Use temperature alarm.

solutions:

-

check the use temperature of the control module; see parameter A4

main consequences:

-

if the alarm occurs when the device is on, a cooking cycle cannot be started

-

if the alarm occurs during an cooking cycle, the cycle will be interrupted

-

the vent will be open, the technical compartment fan will be on and the remaining outputs will

be off

door micro switch input alarm

solutions:

-

check the causes of the activation of the input; see parameter i0

main consequences:

-

if the alarm occurs during a cooking cycle, the temperature regulation output, the fan and the

steam injection output will be switched off and the vent will be open

Circuit breaker

protection ALARM

fan circuit breaker protection input alarm

solutions:

-

check the causes of the activation of the input; see parameters i1 and i2

main consequences:

-

if the alarm occurs during a cooking cycle, the temperature regulation output and the fan will be

switched off

Peak absor.

ALARM

electric absorption input alarm

solutions:

-

check the causes of the activation of the input; see parameter i4

main consequences:

-

if the alarm occurs during an cooking cycle, the outputs will be off

When the problem that caused the error disappears, the device is restored to normal operation.