14.3

List of configuration parameters

The following table illustrates the meaning of the device configuration parameters.

PARAM.

MIN.

MAX.

U.M.

DEF.

ANALOGUE INPUTS

P0

0

2

- - -

0

probe type

0 = thermocouple

J

1 = thermocouple

K

2 = Pt 100 2 wires

P1

0

1

- - -

0

temperature unit of measurement (1)

0 =

°C

1 =

°F

P2

0

1

- - -

0

enabling the needle probe

1 =

YES

P3

0

1

- - -

0

enabling of the steam reduction probe

1 =

YES

CA1

-25/-50

25/50

°C/°F (2)

0

environment probe alarm

CA2

-25/-50

25/50

°C/°F (2)

0

needle probe offset

CA3

-25/-50

25/50

°C/°F (2)

0

steam reduction probe offset

PARAM.

MIN.

MAX.

U.M.

DEF.

MAIN REGULATOR

r0 1 99

°C/°F

(2)

5

work set-point differential (referring to the temperature detected by

the environment probe)

r1 0 r2

°C/°F

(2)

0

work set-point minimum (referring to the temperature detected by

the environment probe)

r2 r1 999

°C/°F

(2)

300

work set-point maximum (referring to the temperature detected by

the environment probe)

r3 r1 r2

°C/°F

(2)

130

work set-point for factory setting (referring to the temperature

detected by the environment probe); see also r0

r4 0 r5

°C/°F

(2)

0

minimum set-point at the core (referring to the temperature

detected by the needle probe)

r5 r4 999

°C/°F

(2)

100

maximum set-point at the core (referring to the temperature

detected by the needle probe)

r6 r4 r5

°C/°F

(2)

30

work set-point at the core for factory setting (referring to the

temperature detected by the needle probe)