3 list of configuration parameters – EVCO EVCSR338J9 User Manual
Page 34

EVCO S.p.A.
Vcolor 338 S | Installer manual ver. 1.2 | Code 144VC338SE124
page 34 of 50
14.3
List of configuration parameters
The following table illustrates the meaning of the device configuration parameters.
PARAM.
MIN.
MAX.
U.M.
DEF.
ANALOGUE INPUTS
P0
0
2
- - -
0
probe type
0 = thermocouple
J
1 = thermocouple
K
2 = Pt 100 2 wires
P1
0
1
- - -
0
temperature unit of measurement (1)
0 =
°C
1 =
°F
P2
0
1
- - -
0
enabling the needle probe
1 =
YES
P3
0
1
- - -
0
enabling of the steam reduction probe
1 =
YES
CA1
-25/-50
25/50
°C/°F (2)
0
environment probe alarm
CA2
-25/-50
25/50
°C/°F (2)
0
needle probe offset
CA3
-25/-50
25/50
°C/°F (2)
0
steam reduction probe offset
PARAM.
MIN.
MAX.
U.M.
DEF.
MAIN REGULATOR
r0 1 99
°C/°F
(2)
5
work set-point differential (referring to the temperature detected by
the environment probe)
r1 0 r2
°C/°F
(2)
0
work set-point minimum (referring to the temperature detected by
the environment probe)
r2 r1 999
°C/°F
(2)
300
work set-point maximum (referring to the temperature detected by
the environment probe)
r3 r1 r2
°C/°F
(2)
130
work set-point for factory setting (referring to the temperature
detected by the environment probe); see also r0
r4 0 r5
°C/°F
(2)
0
minimum set-point at the core (referring to the temperature
detected by the needle probe)
r5 r4 999
°C/°F
(2)
100
maximum set-point at the core (referring to the temperature
detected by the needle probe)
r6 r4 r5
°C/°F
(2)
30
work set-point at the core for factory setting (referring to the
temperature detected by the needle probe)