Vcolor 338 S | Installer manual ver. 1.2 | Code 144VC338SE124

page 17 of 50

6

MANAGEMENT OF UTILITIES

6.1

Preliminary notes

This paragraph illustrates the activity of the utilities during

normal operation.

To know the main consequences of an alarm, see chapter 16

“ALARMS”.

6.2

Temperature regulation

The output is switched on until the environment temperature

reaches the work set-point and is turned back on when the

temperature drops below that established with the parameter

r0 (i.e. "working set-point - r0").

To set the work set-point, see paragraph 8.2 “Setting the

cooking cycle”; to set the configuration parameters, see

paragraph 14.2 “Setting the configuration parameters”.

6.3

Steam injection

The steam generation mode depends on parameter t0, as

follows:

-

if the parameter t0 is set at 0, the steam will be

generated in direct load

-

if the parameter t0 is set at 1, the steam will be

generated with an external humidifier

-

if the parameter t0 is set at 2, the steam will be

generated in combined mode (i.e. direct and with

external humidifier); in this case the temperature

established with parameter t12 establishes the

temperature above which the injection of the

steam generated directly will be activated and

below which the injection of steam generated with

external humidifier will be activated (referring to

the temperature detected by the environment

probe).

The parameter t1 establishes the cycle time for the injection of

the steam generated in direct mode and the parameter t2 the

duration of the injection of the steam generated with the same

mode corresponding to the maximum humidification.

The parameter t6 establishes the cycle time for the injection of

the steam generated with external humidifier and the

parameter t7 the duration of the injection of the steam

generated with the same mode corresponding to the maximum

humidification.

To set the humidification, see paragraph 8.2 “Setting the

cooking cycle”; to set the configuration parameters, see

paragraph 14.2

“Setting the configuration parameters”.

6.4

Vents

The utility managed by the vent output, depends on parameter

u0, as follows:

-

if the parameter u0 is set at 0, the utility will be

an on/off electrovalve

-

if the parameter u0 is set at 1, the utility will be a

motorised electrovalve

The vent is opened automatically on conclusion of each phase

of a cooking cycle.

To set the duration of the automatic vent opening, see the

paragraph 8.2 “Setting the cooking cycle”.

The vent is also opened/closed by touching the area

.

6.5

Room light

The environment light is switched on/off by touching the area

.

6.6

Technical compartment fan

The technical compartment fan is on until the temperature of

use of the control module reaches the temperature established

with parameter F6 and is switched back on when the

temperature rises above that established with parameter F7

(i.e. “F6 + F7”).

To set the configuration parameters, see paragraph 14.2

“Setting the configuration parameters”.

6.7

Fan

The type of ventilation management depends on parameter

F0, in the following way:

-

if the parameter F0 is set at 0, ventilation will be

managed in “on/off” mode and at single speed

-

if the parameter F0 is set at 1, ventilation will be

managed in “on/off” mode and at single speed and

with inversion of the fan rotation direction

-

if the parameter F0 is set at 2, ventilation will be

managed in “on/off” mode and at dual speed and

with inversion of the fan rotation direction

-

if the parameter F0 is set at 3, ventilation will be

managed in modulating mode and with inversion

of the fan rotation direction

If parameter F0 is set at 0, 1 or 2, parameter F1 will establish

the duration of fan switch off due to the inversion of the

direction of rotation of the same and parameter F2 that of fan

switch-on for every direction of rotation.

If parameter F0 is set at 3, parameter F4 will establish

minimum fan speed and parameter F5 the maximum (intended

as a percentage of maximum speed).

To set the fan speed, see paragraph 8.2 “Setting the cooking

cycle”; to set the configuration parameters, see paragraph

14.2 “Setting the configuration parameters”.