Chapter 1 Specifications

1-3

1

ENGLISH

1-2 Specifications

*

1 Evaluated in combination with the SL-C Series

*

2 For the correct performance of the SL-R11E, limit the wiring resistance of the

device connected to the OSSD to 10 Ω.

*

3 The OFF → ON return time is 146 ms.

1-3 External Dimensions Diagram

11

(0.43")

100

(3.94")

24

(0.94")

35 (1.38")

2-ш4.2

(96.6 (3.8"))

25.8

(1.02")

35.9

(1.41")

111

(4.37")

(ш0.17")

2-ш4.2

SL-U2

SL-R11E

3.5 (0.14")

(102.3 (4.03"))

3.5

(0.14")

(112 (4.41"))

49.8

(1.96")

35.9

(1.41")

83.8 (3.3")

11 (0.43")

(ø0.17")

11 (0.43")

48 (1.89")

23 (0.91")

23 (0.91")

135

(5.31")

124

(4.89")

37

(1.46")

Model
Safety Light Curtain
Rating

Power supply voltage
Current consumption

Output

OSSD1, 2

Output type
Maximum load current
Residual voltage (ON)
Leak current
Maximum load capacity
Load wiring resistance

AUX

PNP
NPN

Response time OSSD1, 2, AUX
Response time during E-STOP input
Environmental Protective structure
specifications

Ambient temperature
Storage ambient temperature
Relative humidity
Storage ambient humidity
Vibration

Shock

Material
Weight
Approved EMC

EMS

standards *

1

EMI

Safety

SL-R11E
SL-C Series
24V DC ±10% ripple (P-P) 10% max.
100mA max. (for SL-R11E only)
PNP open collector
500 mA
2V
100

A max.

2.2

F(with 100-_load resistance)

10-

_max.*

2

24 VDC,5 mA max.,residual voltage:2V max.

20ms (including sensor response time)*

3

20ms
IP20 (IEC60529) (Install in control panels equal to or
greater than IP54)
-10 to +55 °C (No frost)
-10 to +60 °C (No frost)
35 to 85% RH (No condensation)
35 to 95% RH
10 to 55 Hz double amplitude width 0.7 mm, 20 sweeps
each for X, Y, Z directions
100 m/s

2

(Approx. 10G) 16ms pulse, in X, Y, Z directions

1,000 times each axis
Polycarbonate
350 g max.
UL61496-1
FCC Part 15B Class A
UL61496-1 (type 4 ESPE)
UL61496-2 (type 4 AOPD)
UL508