4-3-1 Wiring to Start/Restart Input Terminals
The start/restart input terminals are used to connect a signal input (switch, etc.) to cancel the interlock
condition when the machine starts/restarts is run.
To use the start/restart interlock function and E-STOP function, a signal input, such as a switch, must be
connected to this input terminal. Refer to the following wiring diagram when wiring.
Wiring diagram
Start / Restart
input
TEST input
M/S SELECT
input
MPCE
MONITOR input
E-STOP1
input
E-STOP2
input
Timing chart
ON
OFF
ON
OFF
Start/Restart
input
OSSD
35ms
10 ms. min.
WARNING
• When wiring the signal input, such as a switch, to this terminal, install the mecha-
nism used to reset the interlock in a position from which the condition of the
entire hazardous zone can be checked. Do not install the reset mechanism in a
position where it can be operated within the hazardous zone.
• Confirm that there are no people or objects in the hazardous zone before operat-
ing the start/restart input means.
CAUTION
• Use a normally open device, for the start/restart input.
• The start/restart input terminals connect to the 24V DC output terminal. There-
fore, the device, using the start/restart input must be rated for 24V DC or higher.
However, because this terminal is only used for start/restart input, it cannot be
used to supply power to other devices.