4 wiring, 1 method for connection to the sl-c series, 2 method for wiring to the input output terminal – KEYENCE SL-R11E User Manual
Page 27: English, Warning, Chapter 4 wiring
Chapter 4 Wiring
4-1
4
ENGLISH
Terminal No.
Name
1
OSSD 1
2
OSSD 2
3
4
AUX(PNP)
5
AUX(NPN)
6
Power OFF input
7
8
+ 24V*
2
9
0V
OSSD1
OSSD2
AUX(PNP)
AUX(NPN)
MPCE1
MPCE2
*
1 The power OFF input cannot be used when the SL-U2 power supply is
connected to the side of the SL-R11 with a connector.
*
2 The +24-V terminal cannot be used when the SL-U2 power supply is
connected to the side of the SL-R11E with a connector.
No external power supply is needed when the SL-U2 power supply is
connected to the side of the SL-R11E with a connector.
+24V
0V
T R
POWER
FSD-ON
FSD-OFF
INTERLOCK
LOCKOUT
RESTART
TEST
MPCE
E-STOP1
E-STOP2
1
2
3
4
5
6
7
8
9
See Instruction Man
ual.
OFF input
MODE SWITCH
MPCE
MONITOR
START
INTERLOCK
RESTART
INTERLOCK
1,5
2,6
3,7
4,8
MODE SWITCH
MPCE
MONITOR
START
INTERLOCK
RESTART
INTERLOCK
1,5
2,6
3,7
4,8
MPCE 1
MPCE 2
IN
OUT
PLC
Solid state contact
24V
0V
T R
POWER
FSD-ON
FSD-OFF
INTERLOCK
LOCKOUT
RESTART
TEST
MPCE
E-STOP1
E-STOP2
See Instruction Man
ual.
MODE SWITCH
MPCE
MONITOR
START
INTERLOCK
RESTART
INTERLOCK
1,5
2,6
3,7
4,8
*2
*1
*2
4 Wiring
4-1 Method for Connection to the SL-C Series
WARNING
• The SL-C Series can be connected to the SL-R11E using only the following
cable combinations: SL-PC5P/SL-PC10P and SL-CC10PT/SL-CC10PR. When
connecting the SL-CHM Series, only the following cable combinations can be
used: SL-MPC10P, SL-CC10PT, and SI-CC10PR.
• The maximum length of the SL-C Series connection cables (transmitter and
receiver cables) is 30m (98.43 ft.) each.
• Using cables that exceed 30m (98.43 ft.) in length could result in unstable opera-
tion of the SL-C Series and SL-R11E and cause a serious accident leading to
serious injury or death of the machine operator.
Use the special cables to connect the SL-C and SL-R11E as shown in the figure below. Connect and secure
the cables from the SL-C to the connectors for receiver and transmitter provided on the SL-R11E.
Connection 2
Connection 1
Connector for Receiver (black)
Connector for transmitter (gray)
Transmitter cable (gray)
SL-PC PT or
SL-CC10PT
Receiver cable (black)
SL-PC PR
or SL-CC10PR
* Use the following minimum bend radius when routing SL-C Series cables: 10mm (0.39") or greater for the
base of the connector that is connected to the SL-R11E, and 5mm (0.2") or greater for all other positions.
4-2 Method for Wiring to the Input Output Terminal
As shown in the table below, the SL-R11E has a input output terminal block.
Input output terminal
Wiring example