beautypg.com

4 power supply precautions, 4-2 recommended dedicated power supply unit, English – KEYENCE SL-R11E User Manual

Page 10: English 1-4 power supply precautions

background image

Chapter 1 Specifications

1-4

1

English

ENGLISH

1-4 Power Supply Precautions

1-4-1 Power Units that Can Be Used as Power Supplies for SL-C Series and SL-R11E

The power supply units that can be used as the power supply for SL-C Series and SL-R11E must completely
satisfy the following requirements in order to satisfy the requirements of UL61496-1 for the SL-C Series and
SL-R11E.

(a) Rated output voltage is 24V DC ±10%.
(b) The power supply to be used shall be a dedicated power supply for the SL-C Series and/or SL-R11E and

shall not be used to supply power to other devices.

(c) The power supply output must satisfy the requirements for a Class 2 Circuit or Limited Voltage/Current

Circuit as prescribed by UL508. (This requirement applies only when the SL-C is to be used in North
America.)

(d) The power supply must comply with the laws, regulations, and standards covering electrical safety,

electromagnetic compatibility (EMC), etc., for the country or region in which the SL-C Series and/or SL-
R11E will be used.

(e) The output hold time is 20 ms min.

1-4-2 Recommended Dedicated Power Supply Unit

The SL-U2 is offered as the SL-C Series dedicated power supply. The SL-U2 is a power supply that
completely satisfies the above requirements.

Standard

EN60950-1

Safety EN50178
standard

UL60950-1 (R/C)
UL508 (Listing)
EN55011 Class A

EMC standard

EN61000-6-2
FCC Part 15B Class A

SL-U2

24V DC

100 to

240 V AC

+

PE (GND)*

SL-U2

OC

+

-

N

L

CA
UTION

100-240V A

C

ONL

Y

(*) The PE terminal is a protective conductor terminal that must be connected to a protective earthing